{"title":"Viltrus M-Bus to Modbus Converters | UK Supplier","description":"\u003cdiv class=\"ssm-catalogue\"\u003e\n  \u003cheader class=\"ssm-catalogue-intro\"\u003e\n    \u003cp\u003eThe \u003cstrong\u003eViltrus MB Series M-Bus to Modbus converters\u003c\/strong\u003e provide a practical interface between wired M-Bus meters and Modbus RTU monitoring and building-management systems. Available in \u003cstrong\u003eMB-10, MB-50, MB-80, MB-100 and MB-250\u003c\/strong\u003e versions, the range supports networks of up to 250 M-Bus devices, with RS485 or RS232 communication options.\u003c\/p\u003e\n  \u003c\/header\u003e\n\n  \u003csection class=\"ssm-manufacturer\"\u003e\n    \u003cdiv class=\"ssm-manufacturer-header\"\u003e\n      \u003cdiv class=\"ssm-manufacturer-heading\"\u003e\n        \u003ch2\u003eViltrus M-Bus to Modbus RTU Converters\u003c\/h2\u003e\n        \u003cp\u003eReliable integration of M-Bus heat, water and energy meters with Modbus-based control and monitoring systems.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"padding:0 2px;\"\u003e\n      \u003cp style=\"font-size:16px;line-height:1.7;color:#5f6672;\"\u003eThe \u003cstrong\u003eViltrus MB converter range\u003c\/strong\u003e is designed to collect information from wired M-Bus metering networks and make it available to equipment communicating via \u003cstrong\u003eModbus RTU\u003c\/strong\u003e. This provides an integration route for compatible meters in commercial buildings, plant rooms, communal heating installations and other multi-meter applications.\u003c\/p\u003e\n      \u003cp style=\"font-size:16px;line-height:1.7;color:#5f6672;\"\u003eFive models are available to suit different network sizes. Each model can be specified with an \u003cstrong\u003eRS485 or RS232\u003c\/strong\u003e interface, allowing the converter to be matched to the receiving system. The devices feature DIN-rail mounting, galvanic isolation and protection against M-Bus line short circuits.\u003c\/p\u003e\n\n      \u003cdiv style=\"margin:26px 0 0;padding:26px 28px;background:#f7f9fb;border:1px solid #e5e7eb;border-radius:12px;\"\u003e\n        \u003ch3 style=\"margin:0 0 16px;font-size:21px;line-height:1.3;color:#222831;\"\u003eViltrus MB Series at a Glance\u003c\/h3\u003e\n        \u003cul style=\"margin:0;padding-left:22px;font-size:15px;line-height:1.9;color:#5f6672;\"\u003e\n          \u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Wired M-Bus to Modbus RTU conversion\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eModels:\u003c\/strong\u003e MB-10, MB-50, MB-80, MB-100 and MB-250\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eM-Bus capacity:\u003c\/strong\u003e Up to 10, 50, 80, 100 or 250 devices, depending on model\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eModbus interfaces:\u003c\/strong\u003e RS485 or RS232 versions\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 12–36 VDC\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Galvanic isolation and M-Bus short-circuit protection\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e DIN-rail-mountable enclosure\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e Meter data integration, BMS and energy monitoring\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"margin:26px 0 0;\"\u003e\n        \u003ch3 style=\"margin:0 0 12px;font-size:21px;line-height:1.3;color:#222831;\"\u003eChoose the Correct MB Converter\u003c\/h3\u003e\n        \u003cp style=\"font-size:16px;line-height:1.7;color:#5f6672;\"\u003eSelect a converter according to the number of M-Bus devices on the network and the serial interface required by the receiving Modbus equipment.\u003c\/p\u003e\n        \u003cdiv style=\"overflow-x:auto;\"\u003e\n          \u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;line-height:1.6;color:#5f6672;\"\u003e\n            \u003cthead\u003e\u003ctr style=\"background:#f7f9fb;color:#222831;\"\u003e\n\u003cth style=\"padding:12px;border:1px solid #e5e7eb;text-align:left;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:12px;border:1px solid #e5e7eb;text-align:left;\"\u003eMaximum M-Bus devices\u003c\/th\u003e\n\u003cth style=\"padding:12px;border:1px solid #e5e7eb;text-align:left;\"\u003eInterface options\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n            \u003ctbody\u003e\n              \u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003eMB-10\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003e10\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003eRS485 \/ RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n              \u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003eMB-50\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003e50\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003eRS485 \/ RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n              \u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003eMB-80\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003e80\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003eRS485 \/ RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n              \u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003eMB-100\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003e100\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003eRS485 \/ RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n              \u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003eMB-250\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003e250\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #e5e7eb;\"\u003eRS485 \/ RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n            \u003c\/tbody\u003e\n          \u003c\/table\u003e\n        \u003c\/div\u003e\n        \u003cp style=\"font-size:15px;line-height:1.7;color:#5f6672;\"\u003eThe model number indicates the maximum supported M-Bus device count. Check the total M-Bus load and compatibility of the connected meters before specifying the converter.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"margin:26px 0 0;\"\u003e\n        \u003ch3 style=\"margin:0 0 12px;font-size:21px;line-height:1.3;color:#222831;\"\u003eM-Bus to Modbus RTU Integration\u003c\/h3\u003e\n        \u003cp style=\"font-size:16px;line-height:1.7;color:#5f6672;\"\u003eM-Bus is widely used for reading heat, water and other utility meters, whereas Modbus RTU is commonly used by controllers and building-management equipment. The Viltrus MB series provides an interface between these systems, reducing the need for separate manual meter-reading arrangements.\u003c\/p\u003e\n        \u003cp style=\"font-size:16px;line-height:1.7;color:#5f6672;margin-bottom:0;\"\u003eThe MB range is intended for \u003cstrong\u003eserial Modbus RTU\u003c\/strong\u003e communication. Do not confuse RS485\/RS232 versions with a native Modbus TCP\/Ethernet converter. Confirm the required meter data points, register mapping and commissioning settings for your application.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"margin:26px 0 0;padding:26px 28px;background:#f7f9fb;border:1px solid #e5e7eb;border-radius:12px;\"\u003e\n        \u003ch3 style=\"margin:0 0 14px;font-size:21px;line-height:1.3;color:#222831;\"\u003eTechnical Specifications\u003c\/h3\u003e\n        \u003cul style=\"margin:0;padding-left:22px;font-size:15px;line-height:1.9;color:#5f6672;\"\u003e\n          \u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12–36 VDC\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eM-Bus line voltage:\u003c\/strong\u003e Mark 36–40 V; Space 24–27 V\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eM-Bus data transfer speed:\u003c\/strong\u003e 300–9,600 baud (manufacturer specification table)\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eRS485 direction control:\u003c\/strong\u003e Automatic\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eShort-circuit protection:\u003c\/strong\u003e 500 mA triggering current\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eShort-circuit response:\u003c\/strong\u003e Programmable 1–4 seconds; recovery 10–60 seconds\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Galvanic isolation between power, M-Bus and RS485 interfaces; insulation breakdown voltage greater than 1.5 kV\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e Up to 3.5 W without connected devices; up to 20 W fully loaded\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eIndication:\u003c\/strong\u003e LED\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 45 × 75 × 105 mm\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eOperating environment:\u003c\/strong\u003e −25°C to +60°C; up to 95% RH, non-condensing\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp style=\"margin:14px 0 0;font-size:14px;line-height:1.7;color:#5f6672;\"\u003eNote: The manufacturer's overview also mentions baud rates up to 38,400 bit\/s, while its technical specification table states 300–9,600 baud for data transfer. Confirm the required serial settings against the specific model datasheet before ordering.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"margin:26px 0 0;\"\u003e\n        \u003ch3 style=\"margin:0 0 12px;font-size:21px;line-height:1.3;color:#222831;\"\u003eTypical Applications\u003c\/h3\u003e\n        \u003cul style=\"margin:0;padding-left:22px;font-size:15px;line-height:1.9;color:#5f6672;\"\u003e\n          \u003cli\u003eIntegration of wired M-Bus heat meters into Modbus RTU systems\u003c\/li\u003e\n          \u003cli\u003eCommunal heating and multi-tenant metering installations\u003c\/li\u003e\n          \u003cli\u003eCommercial building-management systems\u003c\/li\u003e\n          \u003cli\u003ePlant-room energy monitoring and metering networks\u003c\/li\u003e\n          \u003cli\u003eCentralised water and thermal energy data collection\u003c\/li\u003e\n          \u003cli\u003eIndustrial monitoring and control applications\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"margin:26px 0 0;padding:26px 28px;background:#f7f9fb;border:1px solid #e5e7eb;border-radius:12px;\"\u003e\n        \u003ch3 style=\"margin:0 0 12px;font-size:21px;line-height:1.3;color:#222831;\"\u003eNeed Help Selecting a Viltrus Converter?\u003c\/h3\u003e\n        \u003cp style=\"margin:0;font-size:15px;line-height:1.8;color:#5f6672;\"\u003eContact \u003cstrong\u003eStockshed Metering\u003c\/strong\u003e with the number and type of M-Bus meters, the required \u003cstrong\u003eRS485 or RS232\u003c\/strong\u003e connection and details of the Modbus RTU monitoring system. We can help identify a suitable MB converter for your installation.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\u003c\/div\u003e\n","products":[{"product_id":"viltrus-mb-10-m-bus-to-modbus-converter","title":"Viltrus MB-10 M-Bus to Modbus RTU Converter – 10 Meters","description":"\u003cp\u003eThe \u003cstrong\u003eViltrus MB-10 M-Bus to Modbus RTU Converter\u003c\/strong\u003e connects up to \u003cstrong\u003e10 M-Bus meters\u003c\/strong\u003e to Modbus-based monitoring and building management systems. Choose the RS485 or RS232 interface to suit your controller or gateway.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports up to 10 M-Bus devices (subject to installation loading)\u003c\/li\u003e\n\u003cli\u003eConverts M-Bus metering data for Modbus RTU communication\u003c\/li\u003e\n\u003cli\u003eRS485 and RS232 interface versions available\u003c\/li\u003e\n\u003cli\u003e12–36 VDC power supply\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between interfaces and power\u003c\/li\u003e\n\u003cli\u003eM-Bus short-circuit protection\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting; compact 45 × 75 × 105 mm enclosure\u003c\/li\u003e\n\u003cli\u003eLED operating, transmit, receive and fault indications\u003c\/li\u003e\n\u003cli\u003eOperating temperature: −25°C to +60°C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eIntegration of M-Bus heat, water, electricity and gas meters into Modbus RTU monitoring, BMS, SCADA and industrial control networks. Confirm meter compatibility, bus loading and communication settings before ordering.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/stockshed.uk\/files\/viltrus\/M-Bus-to-Modbus-Converter_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Viltrus","offers":[{"title":"RS485","offer_id":60057067880793,"sku":"MB-10","price":170.65,"currency_code":"GBP","in_stock":true},{"title":"RS232","offer_id":60057067913561,"sku":"MB-10-RS232","price":170.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/Viltrus_MB-80_Industrial_Converter_Module.png?v=1792596396"},{"product_id":"viltrus-mb-50-m-bus-to-modbus-converter","title":"Viltrus MB-50 M-Bus to Modbus RTU Converter – 50 Meters","description":"\u003cp\u003eThe \u003cstrong\u003eViltrus MB-50 M-Bus to Modbus RTU Converter\u003c\/strong\u003e connects up to \u003cstrong\u003e50 M-Bus meters\u003c\/strong\u003e to Modbus-based monitoring and building management systems. Choose the RS485 or RS232 interface to suit your controller or gateway.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports up to 50 M-Bus devices (subject to installation loading)\u003c\/li\u003e\n\u003cli\u003eConverts M-Bus metering data for Modbus RTU communication\u003c\/li\u003e\n\u003cli\u003eRS485 and RS232 interface versions available\u003c\/li\u003e\n\u003cli\u003e12–36 VDC power supply\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between interfaces and power\u003c\/li\u003e\n\u003cli\u003eM-Bus short-circuit protection\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting; compact 45 × 75 × 105 mm enclosure\u003c\/li\u003e\n\u003cli\u003eLED operating, transmit, receive and fault indications\u003c\/li\u003e\n\u003cli\u003eOperating temperature: −25°C to +60°C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eIntegration of M-Bus heat, water, electricity and gas meters into Modbus RTU monitoring, BMS, SCADA and industrial control networks. Confirm meter compatibility, bus loading and communication settings before ordering.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/stockshed.uk\/files\/viltrus\/M-Bus-to-Modbus-Converter_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Viltrus","offers":[{"title":"RS485","offer_id":60057068110169,"sku":"MB-50","price":188.93,"currency_code":"GBP","in_stock":true},{"title":"RS232","offer_id":60057068142937,"sku":"MB-50-RS232","price":188.93,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/Viltrus_MB-80_Industrial_Converter_Module.png?v=1792596396"},{"product_id":"viltrus-mb-80-m-bus-to-modbus-converter","title":"Viltrus MB-80 M-Bus to Modbus RTU Converter – 80 Meters","description":"\u003cp\u003eThe \u003cstrong\u003eViltrus MB-80 M-Bus to Modbus RTU Converter\u003c\/strong\u003e connects up to \u003cstrong\u003e80 M-Bus meters\u003c\/strong\u003e to Modbus-based monitoring and building management systems. Choose the RS485 or RS232 interface to suit your controller or gateway.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports up to 80 M-Bus devices (subject to installation loading)\u003c\/li\u003e\n\u003cli\u003eConverts M-Bus metering data for Modbus RTU communication\u003c\/li\u003e\n\u003cli\u003eRS485 and RS232 interface versions available\u003c\/li\u003e\n\u003cli\u003e12–36 VDC power supply\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between interfaces and power\u003c\/li\u003e\n\u003cli\u003eM-Bus short-circuit protection\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting; compact 45 × 75 × 105 mm enclosure\u003c\/li\u003e\n\u003cli\u003eLED operating, transmit, receive and fault indications\u003c\/li\u003e\n\u003cli\u003eOperating temperature: −25°C to +60°C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eIntegration of M-Bus heat, water, electricity and gas meters into Modbus RTU monitoring, BMS, SCADA and industrial control networks. Confirm meter compatibility, bus loading and communication settings before ordering.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/stockshed.uk\/files\/viltrus\/M-Bus-to-Modbus-Converter_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Viltrus","offers":[{"title":"RS485","offer_id":60057068306777,"sku":"MB-80","price":213.31,"currency_code":"GBP","in_stock":true},{"title":"RS232","offer_id":60057068339545,"sku":"MB-80-RS232","price":213.31,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/Viltrus_MB-80_Industrial_Converter_Module.png?v=1792596396"},{"product_id":"viltrus-mb-100-m-bus-to-modbus-converter","title":"Viltrus MB-100 M-Bus to Modbus RTU Converter – 100 Meters","description":"\u003cp\u003eThe \u003cstrong\u003eViltrus MB-100 M-Bus to Modbus RTU Converter\u003c\/strong\u003e connects up to \u003cstrong\u003e100 M-Bus meters\u003c\/strong\u003e to Modbus-based monitoring and building management systems. Choose the RS485 or RS232 interface to suit your controller or gateway.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports up to 100 M-Bus devices (subject to installation loading)\u003c\/li\u003e\n\u003cli\u003eConverts M-Bus metering data for Modbus RTU communication\u003c\/li\u003e\n\u003cli\u003eRS485 and RS232 interface versions available\u003c\/li\u003e\n\u003cli\u003e12–36 VDC power supply\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between interfaces and power\u003c\/li\u003e\n\u003cli\u003eM-Bus short-circuit protection\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting; compact 45 × 75 × 105 mm enclosure\u003c\/li\u003e\n\u003cli\u003eLED operating, transmit, receive and fault indications\u003c\/li\u003e\n\u003cli\u003eOperating temperature: −25°C to +60°C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eIntegration of M-Bus heat, water, electricity and gas meters into Modbus RTU monitoring, BMS, SCADA and industrial control networks. Confirm meter compatibility, bus loading and communication settings before ordering.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/stockshed.uk\/files\/viltrus\/M-Bus-to-Modbus-Converter_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Viltrus","offers":[{"title":"RS485","offer_id":60057068831065,"sku":"MB-100","price":274.27,"currency_code":"GBP","in_stock":true},{"title":"RS232","offer_id":60057068863833,"sku":"MB-100-RS232","price":274.27,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/Viltrus_MB-80_Industrial_Converter_Module.png?v=1792596396"},{"product_id":"viltrus-mb-250-m-bus-to-modbus-converter","title":"Viltrus MB-250 M-Bus to Modbus RTU Converter – 250 Meters","description":"\u003cp\u003eThe \u003cstrong\u003eViltrus MB-250 M-Bus to Modbus RTU Converter\u003c\/strong\u003e connects up to \u003cstrong\u003e250 M-Bus meters\u003c\/strong\u003e to Modbus-based monitoring and building management systems. Choose the RS485 or RS232 interface to suit your controller or gateway.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports up to 250 M-Bus devices (subject to installation loading)\u003c\/li\u003e\n\u003cli\u003eConverts M-Bus metering data for Modbus RTU communication\u003c\/li\u003e\n\u003cli\u003eRS485 and RS232 interface versions available\u003c\/li\u003e\n\u003cli\u003e12–36 VDC power supply\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between interfaces and power\u003c\/li\u003e\n\u003cli\u003eM-Bus short-circuit protection\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting; compact 45 × 75 × 105 mm enclosure\u003c\/li\u003e\n\u003cli\u003eLED operating, transmit, receive and fault indications\u003c\/li\u003e\n\u003cli\u003eOperating temperature: −25°C to +60°C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eIntegration of M-Bus heat, water, electricity and gas meters into Modbus RTU monitoring, BMS, SCADA and industrial control networks. Confirm meter compatibility, bus loading and communication settings before ordering.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/stockshed.uk\/files\/viltrus\/M-Bus-to-Modbus-Converter_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Viltrus","offers":[{"title":"RS485","offer_id":60057069027673,"sku":"MB-250","price":341.32,"currency_code":"GBP","in_stock":true},{"title":"RS232","offer_id":60057069060441,"sku":"MB-250-RS232","price":341.32,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/Viltrus_MB-80_Industrial_Converter_Module.png?v=1792596396"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/collections\/Viltrus_MB-80_Industrial_Converter_Module.png?v=1792596407","url":"https:\/\/stockshedmetering.com\/collections\/viltrus-mbus-to-modbus-converters.oembed","provider":"Stockshed Metering Limited","version":"1.0","type":"link"}