{"title":"BEKA Rate Totalisers – Externally Powered Field","description":"\u003cp\u003eExplore BEKA Associates rate totalisers – externally powered field available from Stockshed Metering. Contact us for assistance with options, certifications and product selection.\u003c\/p\u003e","products":[{"product_id":"beka-ba334e","title":"BEKA BA334E – Rate Totaliser","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA334E\u003c\/strong\u003e is an intrinsically safe flow rate totaliser for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e10–28 V DC via a suitable barrier or galvanic isolator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupported pulse signals\u003c\/th\u003e\n\u003ctd\u003eSwitch contact, NAMUR proximity detector, open collector, magnetic pick-up, voltage pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePulse inputs\u003c\/th\u003e\n\u003ctd\u003eOne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplayed values\u003c\/th\u003e\n\u003ctd\u003eFlow rate and accumulated total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard output\u003c\/th\u003e\n\u003ctd\u003eIsolated pulse output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAdditional outputs\u003c\/th\u003e\n\u003ctd\u003eDual alarms and isolated 4–20 mA output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinearisation\u003c\/th\u003e\n\u003ctd\u003eUp to 16 K-factors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003ePrimary: 8 digits 18 mm high \/ Secondary: 6 digits 12 mm high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFront dimensions\u003c\/th\u003e\n\u003ctd\u003e141 × 212 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous-area protection\u003c\/th\u003e\n\u003ctd\u003eIntrinsically safe Ex ia. Refer to BEKA certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−40 to +70 °C. Display range −20 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba334e_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA334E datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373830435161,"sku":"BA334E","price":945.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba334e_large_ab3acf9e-c318-43de-ba03-95545ab0a1ff.png?v=1793874512"},{"product_id":"beka-ba334g","title":"BEKA BA334G – Rate Totaliser","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA334G\u003c\/strong\u003e is an intrinsically safe flow rate totaliser for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e10–28 V DC via a suitable barrier or galvanic isolator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupported pulse signals\u003c\/th\u003e\n\u003ctd\u003eSwitch contact, NAMUR proximity detector, open collector, magnetic pick-up, voltage pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePulse inputs\u003c\/th\u003e\n\u003ctd\u003eOne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplayed values\u003c\/th\u003e\n\u003ctd\u003eFlow rate and accumulated total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard output\u003c\/th\u003e\n\u003ctd\u003eIsolated pulse output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFactory options\u003c\/th\u003e\n\u003ctd\u003eBacklight, dual alarms and isolated 4–20 mA output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinearisation\u003c\/th\u003e\n\u003ctd\u003eUp to 16 K-factors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003ePrimary: 8 digits 18 mm high \/ Secondary: 6 digits 12 mm high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFront dimensions\u003c\/th\u003e\n\u003ctd\u003e122 × 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous-area protection\u003c\/th\u003e\n\u003ctd\u003eIntrinsically safe Ex ia. Refer to BEKA certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−40 to +70 °C. Display range −20 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba334g_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA334G datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373830467929,"sku":"BA334G","price":549.33,"currency_code":"GBP","in_stock":true},{"title":"With backlight","offer_id":60373830500697,"sku":"BA334G-BL","price":618.67,"currency_code":"GBP","in_stock":true},{"title":"With dual alarms","offer_id":60373830533465,"sku":"BA334G-ALM","price":630.67,"currency_code":"GBP","in_stock":true},{"title":"With backlight and dual alarms","offer_id":60373830566233,"sku":"BA334G-BL-ALM","price":700.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba334g_large_07265d35-5fe6-44e4-a18a-f0f06b14caa5.png?v=1793874512"},{"product_id":"beka-ba384e","title":"BEKA BA384E – Rate Totaliser","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA384E\u003c\/strong\u003e is an intrinsically safe flow rate totaliser for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e10–28 V DC via a suitable barrier or galvanic isolator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupported pulse signals\u003c\/th\u003e\n\u003ctd\u003eSwitch contact, NAMUR proximity detector, open collector, magnetic pick-up, voltage pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePulse inputs\u003c\/th\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplayed values\u003c\/th\u003e\n\u003ctd\u003eFlow rate and accumulated total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard output\u003c\/th\u003e\n\u003ctd\u003eIsolated pulse output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAdditional outputs\u003c\/th\u003e\n\u003ctd\u003eDual alarms and isolated 4–20 mA output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinearisation\u003c\/th\u003e\n\u003ctd\u003eUp to 16 K-factors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003ePrimary: 8 digits 18 mm high \/ Secondary: 6 digits 12 mm high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFront dimensions\u003c\/th\u003e\n\u003ctd\u003e141 × 212 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous-area protection\u003c\/th\u003e\n\u003ctd\u003eIntrinsically safe Ex ia. Refer to BEKA certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−40 to +70 °C. Display range −20 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba384e_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA384E datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373830599001,"sku":"BA384E","price":948.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba384e_large_567a6e34-e658-4dee-bc6c-0488ecd0cedd.png?v=1793874512"},{"product_id":"beka-ba384g","title":"BEKA BA384G – Rate Totaliser","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA384G\u003c\/strong\u003e is an intrinsically safe flow rate totaliser for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e10–28 V DC via a suitable barrier or galvanic isolator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupported pulse signals\u003c\/th\u003e\n\u003ctd\u003eSwitch contact, NAMUR proximity detector, open collector, magnetic pick-up, voltage pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePulse inputs\u003c\/th\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplayed values\u003c\/th\u003e\n\u003ctd\u003eFlow rate and accumulated total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard output\u003c\/th\u003e\n\u003ctd\u003eIsolated pulse output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFactory options\u003c\/th\u003e\n\u003ctd\u003eBacklight, dual alarms and isolated 4–20 mA output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinearisation\u003c\/th\u003e\n\u003ctd\u003eUp to 16 K-factors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003ePrimary: 8 digits 18 mm high \/ Secondary: 6 digits 12 mm high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFront dimensions\u003c\/th\u003e\n\u003ctd\u003e122 × 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous-area protection\u003c\/th\u003e\n\u003ctd\u003eIntrinsically safe Ex ia. Refer to BEKA certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−40 to +70 °C. Display range −20 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba384g_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA384G datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373830631769,"sku":"BA384G","price":552.0,"currency_code":"GBP","in_stock":true},{"title":"With backlight","offer_id":60373830664537,"sku":"BA384G-BL","price":621.33,"currency_code":"GBP","in_stock":true},{"title":"With dual alarms","offer_id":60373830697305,"sku":"BA384G-ALM","price":633.33,"currency_code":"GBP","in_stock":true},{"title":"With backlight and dual alarms","offer_id":60373830730073,"sku":"BA384G-BL-ALM","price":702.67,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba384g_large_3cb6e46e-c939-4ce9-b75c-754b914967ca.png?v=1793874511"},{"product_id":"beka-ba534g","title":"BEKA BA534G – Rate Totaliser","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA534G\u003c\/strong\u003e is a flow rate totaliser for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e10–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupported pulse signals\u003c\/th\u003e\n\u003ctd\u003eSwitch contact, NAMUR proximity detector, open collector, magnetic pick-up, voltage pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePulse inputs\u003c\/th\u003e\n\u003ctd\u003eOne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplayed values\u003c\/th\u003e\n\u003ctd\u003eFlow rate and accumulated total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard output\u003c\/th\u003e\n\u003ctd\u003eIsolated pulse output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFactory options\u003c\/th\u003e\n\u003ctd\u003eBacklight, dual alarms and isolated 4–20 mA output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinearisation\u003c\/th\u003e\n\u003ctd\u003eUp to 16 K-factors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003ePrimary: 8 digits 18 mm high \/ Secondary: 6 digits 12 mm high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFront dimensions\u003c\/th\u003e\n\u003ctd\u003e122 × 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eGeneral purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−40 to +70 °C. Display range −20 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba534g_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA534G datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373830762841,"sku":"BA534G","price":389.33,"currency_code":"GBP","in_stock":true},{"title":"With backlight","offer_id":60373830795609,"sku":"BA534G-BL","price":449.33,"currency_code":"GBP","in_stock":true},{"title":"With dual alarms","offer_id":60373830828377,"sku":"BA534G-ALM","price":470.67,"currency_code":"GBP","in_stock":true},{"title":"With backlight and dual alarms","offer_id":60373830861145,"sku":"BA534G-BL-ALM","price":530.67,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba534g_large_765c3444-264e-4d19-aee2-76da70fb52f3.png?v=1793874511"},{"product_id":"beka-ba584g","title":"BEKA BA584G – Rate Totaliser","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA584G\u003c\/strong\u003e is a flow rate totaliser for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e10–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupported pulse signals\u003c\/th\u003e\n\u003ctd\u003eSwitch contact, NAMUR proximity detector, open collector, magnetic pick-up, voltage pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePulse inputs\u003c\/th\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplayed values\u003c\/th\u003e\n\u003ctd\u003eFlow rate and accumulated total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard output\u003c\/th\u003e\n\u003ctd\u003eIsolated pulse output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFactory options\u003c\/th\u003e\n\u003ctd\u003eBacklight, dual alarms and isolated 4–20 mA output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinearisation\u003c\/th\u003e\n\u003ctd\u003eUp to 16 K-factors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003ePrimary: 8 digits 18 mm high \/ Secondary: 6 digits 12 mm high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFront dimensions\u003c\/th\u003e\n\u003ctd\u003e122 × 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eGeneral purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−40 to +70 °C. Display range −20 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba584g_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA584G datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373830893913,"sku":"BA584G","price":392.0,"currency_code":"GBP","in_stock":true},{"title":"With backlight","offer_id":60373830926681,"sku":"BA584G-BL","price":452.0,"currency_code":"GBP","in_stock":true},{"title":"With dual alarms","offer_id":60373830959449,"sku":"BA584G-ALM","price":473.33,"currency_code":"GBP","in_stock":true},{"title":"With backlight and dual alarms","offer_id":60373830992217,"sku":"BA584G-BL-ALM","price":533.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba584g_large_341c8cda-a030-4fb8-bbb6-274497270b85.png?v=1793874511"}],"url":"https:\/\/stockshedmetering.com\/collections\/rate-totalisers-externally-powered-field.oembed","provider":"Stockshed Metering Limited","version":"1.0","type":"link"}