{"title":"Landis+Gyr - T230 Ultraheat Heat Energy Meters","description":"\u003cdiv class=\"ssm-catalogue\"\u003e\n\n  \u003cheader class=\"ssm-catalogue-intro\"\u003e\n    \u003cp\u003e\n      The Landis+Gyr ULTRAHEAT T230 is a compact ultrasonic thermal energy meter designed for residential, apartment, local heating and building-services applications. It combines \u003cstrong\u003eaccurate low-flow measurement, flexible installation and intelligent measurement functions\u003c\/strong\u003e in a compact meter platform suitable for heating and cooling applications.\n    \u003c\/p\u003e\n  \u003c\/header\u003e\n\n  \u003c!-- =====================================================\n       PRODUCT OVERVIEW\n       ===================================================== --\u003e\n\n  \u003csection class=\"ssm-manufacturer\"\u003e\n\n    \u003cdiv class=\"ssm-manufacturer-header\"\u003e\n      \u003cdiv class=\"ssm-manufacturer-heading\"\u003e\n        \u003ch2\u003eLandis+Gyr ULTRAHEAT T230 Ultrasonic Energy Meter\u003c\/h2\u003e\n        \u003cp\u003e\n          Compact ultrasonic energy metering for residential and light commercial applications where installation flexibility, accuracy and long-term reliability are important.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"padding: 0 2px;\"\u003e\n\n      \u003cp style=\"font-size: 16px; line-height: 1.7; color: #5f6672;\"\u003e\n        The \u003cstrong\u003eLandis+Gyr ULTRAHEAT T230\u003c\/strong\u003e combines established ultrasonic metering technology with a compact design developed specifically for individual consumption measurement.\n      \u003c\/p\u003e\n\n      \u003cp style=\"font-size: 16px; line-height: 1.7; color: #5f6672;\"\u003e\n        It is particularly well suited to apartments, local heating systems and building-services installations where available space may be restricted but accurate thermal energy measurement is still required.\n      \u003c\/p\u003e\n\n      \u003cp style=\"font-size: 16px; line-height: 1.7; color: #5f6672;\"\u003e\n        The meter uses a composite measuring unit with no moving mechanical measuring parts in the flow channel. This provides excellent long-term stability and helps reduce sensitivity to deposits and normal wear.\n      \u003c\/p\u003e\n\n      \u003c!-- QUICK SPECIFICATION PANEL --\u003e\n\n      \u003cdiv style=\"margin: 26px 0 0; padding: 26px 28px; background: #f7f9fb; border: 1px solid #e5e7eb; border-radius: 12px;\"\u003e\n\n        \u003ch3 style=\"margin: 0 0 16px; font-size: 21px; line-height: 1.3; color: #222831;\"\u003e\n          ULTRAHEAT T230 at a Glance\n        \u003c\/h3\u003e\n\n        \u003cul style=\"margin: 0; padding-left: 22px; font-size: 15px; line-height: 1.9; color: #5f6672;\"\u003e\n          \u003cli\u003e\n\u003cstrong\u003eMeasurement technology:\u003c\/strong\u003e Ultrasonic\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e Heating and cooling energy measurement\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e MID Class 2\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eTemperature range:\u003c\/strong\u003e 5–105°C\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Composite measuring unit with no moving parts in the measuring channel\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eCalculator:\u003c\/strong\u003e Flat, rotatable and detachable\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eLow-flow performance:\u003c\/strong\u003e Designed to measure very small flow rates accurately\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eData storage:\u003c\/strong\u003e Up to 24 months\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e No straight pipe lengths or flow straighteners required\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eTypical use:\u003c\/strong\u003e Apartments, residential developments, local heating and building-services applications\u003c\/li\u003e\n        \u003c\/ul\u003e\n\n      \u003c\/div\u003e\n\n      \u003c!-- COMPACT DESIGN --\u003e\n\n      \u003cdiv style=\"margin: 26px 0 0;\"\u003e\n\n        \u003ch3 style=\"margin: 0 0 12px; font-size: 21px; line-height: 1.3; color: #222831;\"\u003e\n          Compact \u0026amp; Flexible Installation\n        \u003c\/h3\u003e\n\n        \u003cp style=\"font-size: 16px; line-height: 1.7; color: #5f6672;\"\u003e\n          The T230 has been designed specifically for installations where space is limited. Its compact dimensions and flexible mounting options allow it to be fitted in locations such as narrow meter cupboards and restricted service areas.\n        \u003c\/p\u003e\n\n        \u003cp style=\"font-size: 16px; line-height: 1.7; color: #5f6672; margin-bottom: 0;\"\u003e\n          The calculator is \u003cstrong\u003erotatable and detachable\u003c\/strong\u003e, allowing the display to be positioned for convenient reading even where the flow sensor itself must be installed in an awkward or confined location.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n      \u003c!-- ULTRASONIC TECHNOLOGY --\u003e\n\n      \u003cdiv style=\"margin: 26px 0 0; padding: 26px 28px; background: #f7f9fb; border: 1px solid #e5e7eb; border-radius: 12px;\"\u003e\n\n        \u003ch3 style=\"margin: 0 0 12px; font-size: 21px; line-height: 1.3; color: #222831;\"\u003e\n          Proven Ultrasonic Measurement Technology\n        \u003c\/h3\u003e\n\n        \u003cp style=\"margin: 0 0 14px; font-size: 15px; line-height: 1.8; color: #5f6672;\"\u003e\n          Landis+Gyr has extensive experience with ultrasonic heat-meter technology in residential and district-heating applications. The T230 builds on this established measuring principle in a compact meter designed for modern installations.\n        \u003c\/p\u003e\n\n        \u003cp style=\"margin: 0; font-size: 15px; line-height: 1.8; color: #5f6672;\"\u003e\n          With no conventional moving measuring parts in the flow channel, the meter is designed for stable long-term performance and reduced sensitivity to mechanical wear.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n      \u003c!-- DURASURFACE --\u003e\n\n      \u003cdiv style=\"margin: 26px 0 0;\"\u003e\n\n        \u003ch3 style=\"margin: 0 0 12px; font-size: 21px; line-height: 1.3; color: #222831;\"\u003e\n          DuraSurface™ Measuring Stability\n        \u003c\/h3\u003e\n\n        \u003cp style=\"font-size: 16px; line-height: 1.7; color: #5f6672;\"\u003e\n          The T230 measuring unit incorporates Landis+Gyr's \u003cstrong\u003eDuraSurface™\u003c\/strong\u003e internal profile, developed to provide reliable and stable measurement performance over time.\n        \u003c\/p\u003e\n\n        \u003cp style=\"font-size: 16px; line-height: 1.7; color: #5f6672; margin-bottom: 0;\"\u003e\n          The design helps reduce sensitivity to deposits and contamination within the measuring channel, supporting consistent accuracy and dependable long-term operation.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n      \u003c!-- INTELLIGENT FUNCTIONS --\u003e\n\n      \u003cdiv style=\"margin: 26px 0 0; padding: 26px 28px; background: #f7f9fb; border: 1px solid #e5e7eb; border-radius: 12px;\"\u003e\n\n        \u003ch3 style=\"margin: 0 0 12px; font-size: 21px; line-height: 1.3; color: #222831;\"\u003e\n          Intelligent Measurement Functions\n        \u003c\/h3\u003e\n\n        \u003cp style=\"margin: 0 0 14px; font-size: 15px; line-height: 1.8; color: #5f6672;\"\u003e\n          The T230 includes a range of software functions designed to improve measurement accuracy, simplify data handling and provide useful historical information.\n        \u003c\/p\u003e\n\n        \u003cul style=\"margin: 0; padding-left: 22px; font-size: 15px; line-height: 1.9; color: #5f6672;\"\u003e\n          \u003cli\u003eAdaptive measurement\u003c\/li\u003e\n          \u003cli\u003eTemperature compensation\u003c\/li\u003e\n          \u003cli\u003eManual parameterisation\u003c\/li\u003e\n          \u003cli\u003eStatistical values\u003c\/li\u003e\n          \u003cli\u003eMonthly consumption values\u003c\/li\u003e\n          \u003cli\u003eConfigurable due-date values\u003c\/li\u003e\n          \u003cli\u003eData storage for up to 24 months\u003c\/li\u003e\n          \u003cli\u003eTwo monthly set dates\u003c\/li\u003e\n        \u003c\/ul\u003e\n\n      \u003c\/div\u003e\n\n      \u003c!-- INSTALLATION --\u003e\n\n      \u003cdiv style=\"margin: 26px 0 0;\"\u003e\n\n        \u003ch3 style=\"margin: 0 0 12px; font-size: 21px; line-height: 1.3; color: #222831;\"\u003e\n          Straightforward Installation\n        \u003c\/h3\u003e\n\n        \u003cp style=\"font-size: 16px; line-height: 1.7; color: #5f6672;\"\u003e\n          The T230 is designed to simplify installation and commissioning. Its compact size and detachable calculator make it particularly useful where access is restricted.\n        \u003c\/p\u003e\n\n        \u003cp style=\"font-size: 16px; line-height: 1.7; color: #5f6672; margin-bottom: 0;\"\u003e\n          No straight lengths of pipe or additional flow straighteners are required, helping reduce the installation space and pipework modifications needed around the meter.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n      \u003c!-- APPLICATIONS --\u003e\n\n      \u003cdiv style=\"margin: 26px 0 0;\"\u003e\n\n        \u003ch3 style=\"margin: 0 0 14px; font-size: 21px; line-height: 1.3; color: #222831;\"\u003e\n          Typical Applications\n        \u003c\/h3\u003e\n\n        \u003cul style=\"margin: 0; padding-left: 22px; font-size: 15px; line-height: 1.9; color: #5f6672;\"\u003e\n          \u003cli\u003eResidential heat metering\u003c\/li\u003e\n          \u003cli\u003eApartment and flat energy sub-metering\u003c\/li\u003e\n          \u003cli\u003eCommunal heating systems\u003c\/li\u003e\n          \u003cli\u003eLocal heating networks\u003c\/li\u003e\n          \u003cli\u003eBuilding-services installations\u003c\/li\u003e\n          \u003cli\u003eCooling energy measurement\u003c\/li\u003e\n          \u003cli\u003eRestricted meter cupboards\u003c\/li\u003e\n          \u003cli\u003eSystems with variable or low flow rates\u003c\/li\u003e\n          \u003cli\u003eAutomatic meter-reading applications\u003c\/li\u003e\n        \u003c\/ul\u003e\n\n      \u003c\/div\u003e\n\n      \u003c!-- WHY CHOOSE --\u003e\n\n      \u003cdiv style=\"margin: 26px 0 0; padding: 26px 28px; background: #f7f9fb; border: 1px solid #e5e7eb; border-radius: 12px;\"\u003e\n\n        \u003ch3 style=\"margin: 0 0 12px; font-size: 21px; line-height: 1.3; color: #222831;\"\u003e\n          Why Choose the ULTRAHEAT T230?\n        \u003c\/h3\u003e\n\n        \u003cp style=\"margin: 0; font-size: 15px; line-height: 1.8; color: #5f6672;\"\u003e\n          The T230 is particularly well suited to applications where a \u003cstrong\u003ecompact, accurate and installation-friendly ultrasonic energy meter\u003c\/strong\u003e is required. Its detachable calculator, excellent low-flow measurement, long-term measuring stability and intelligent software functions make it a strong choice for residential and apartment energy-metering applications.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n      \u003c!-- SUPPORT --\u003e\n\n      \u003cdiv style=\"margin: 26px 0 0; padding: 26px 28px; background: #f7f9fb; border: 1px solid #e5e7eb; border-radius: 12px;\"\u003e\n\n        \u003ch3 style=\"margin: 0 0 12px; font-size: 21px; line-height: 1.3; color: #222831;\"\u003e\n          Need Help Selecting the Correct T230?\n        \u003c\/h3\u003e\n\n        \u003cp style=\"margin: 0; font-size: 15px; line-height: 1.8; color: #5f6672;\"\u003e\n          Contact Stockshed Metering with your \u003cstrong\u003epipe size, expected flow rate, heating or cooling application and communication requirements\u003c\/strong\u003e and we can help identify the most suitable Landis+Gyr T230 configuration for your installation.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\u003c\/div\u003e","products":[{"product_id":"t230-ultraheat-heat-meter-1-2-bsp-dn15-qp1-5-110mm-t230-a21c","title":"T230 ULTRAHEAT Heat Meter. 1\/2\" BSP (DN15), QP1.5, 110mm. (PN: T230-A21C).","description":"\u003cp\u003eLandis+Gyr T230 ULTRAHEAT ultrasonic heat meter for residential and commercial energy metering applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMID Class 2 approved heat meter.\u003c\/li\u003e\n\u003cli\u003eNominal flow qp 1.5 m3\/h.\u003c\/li\u003e\n\u003cli\u003e110mm body length.\u003c\/li\u003e\n\u003cli\u003ePN16.\u003c\/li\u003e\n\u003cli\u003e3\/4\" BSP meter direct connection.\u003c\/li\u003e\n\u003cli\u003eIncludes 1\/2\" BSP unions and gaskets.\u003c\/li\u003e\n\u003cli\u003eBattery powered.\u003c\/li\u003e\n\u003cli\u003eM-Bus output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/stockshed.uk\/files\/landisgyr\/T230_Technical_Description_Stockshed.pdf\" title=\"Landis+Gyr T230 ULTRAHEAT Heat Energy Meter\" rel=\"noopener\" target=\"_blank\"\u003eDownload Product Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Landis+Gyr Group AG","offers":[{"title":"Default Title","offer_id":58811536343385,"sku":"T230-A21C","price":166.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/T230_Front_700x700_540x_1_be5a3ae7-1050-4f48-b278-48621034718a.webp?v=1786360064"},{"product_id":"t230-ultraheat-heat-meter-3-4-bsp-dn20-qp2-5-130mm-t230-a36c","title":"T230 ULTRAHEAT Heat Meter. 3\/4\" BSP (DN20), QP2.5, 130mm. (PN: T230-A36C).","description":"\u003cp\u003eLandis+Gyr T230 ULTRAHEAT ultrasonic heat meter for residential and commercial energy metering applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMID Class 2 approved heat meter.\u003c\/li\u003e\n\u003cli\u003eNominal flow qp 2.5 m3\/h.\u003c\/li\u003e\n\u003cli\u003e130mm body length.\u003c\/li\u003e\n\u003cli\u003ePN16.\u003c\/li\u003e\n\u003cli\u003e1\" BSP meter direct connection.\u003c\/li\u003e\n\u003cli\u003eIncludes 3\/4\" BSP unions and gaskets.\u003c\/li\u003e\n\u003cli\u003eBattery powered.\u003c\/li\u003e\n\u003cli\u003eM-Bus output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/stockshed.uk\/files\/landisgyr\/T230_Technical_Description_Stockshed.pdf\" title=\"Landis+Gyr T230 ULTRAHEAT Heat Energy Meter\" rel=\"noopener\" target=\"_blank\"\u003eDownload Product Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Landis+Gyr Group AG","offers":[{"title":"Default Title","offer_id":58811536539993,"sku":"T230-A36C","price":171.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/T230_Front_700x700_540x_1_3722c0c1-0c6a-4147-80f1-8cd232d41ed0.webp?v=1786360085"}],"url":"https:\/\/stockshedmetering.com\/collections\/landis-gyr-t230-ultraheat-heat-energy-meters.oembed","provider":"Stockshed Metering Limited","version":"1.0","type":"link"}