{"title":"BEKA Fieldbus Displays","description":"\u003cp\u003eExplore BEKA fieldbus displays available from Stockshed Metering. Find panel and field-mounted industrial instrumentation, compatible options and technical documentation.\u003c\/p\u003e","products":[{"product_id":"beka-ba448cf-p","title":"BEKA BA448CF-P – PROFIBUS PA Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA448CF-P\u003c\/strong\u003e is an intrinsically safe PROFIBUS PA process indicator for panel mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS PA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC subject to the applicable intrinsic safety limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5-digit LCD, 20 mm digits, 31-segment bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePanel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66 front, IP20 rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous-area protection\u003c\/th\u003e\n\u003ctd\u003eIntrinsically safe Ex ia. Refer to BEKA certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba448cf-p_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA448CF-P datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373833711961,"sku":"BA448CF-P","price":698.67,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba448cf_large_6480bd0a-a883-40a4-8c0c-2a6074989211.png?v=1793874504"},{"product_id":"beka-ba488cf-p","title":"BEKA BA488CF-P – PROFIBUS PA Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA488CF-P\u003c\/strong\u003e is an intrinsically safe PROFIBUS PA graphic display for panel mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS PA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC subject to the applicable intrinsic safety limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eGraphic LCD, 120 × 64 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePanel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66 front, IP20 rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous-area protection\u003c\/th\u003e\n\u003ctd\u003eIntrinsically safe Ex ia. Refer to BEKA certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba488cf-p_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA488CF-P datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373833744729,"sku":"BA488CF-P","price":1166.67,"currency_code":"GBP","in_stock":true},{"title":"With dual alarms","offer_id":60373833777497,"sku":"BA488CF-P-ALM","price":1425.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba488cf_large_49b11ca0-74e1-41bc-9c3d-267582067d00.png?v=1793874503"},{"product_id":"beka-ba648cf-p","title":"BEKA BA648CF-P – PROFIBUS PA Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA648CF-P\u003c\/strong\u003e is a PROFIBUS PA process indicator for panel mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS PA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5-digit LCD, 20 mm digits, 31-segment bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePanel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66 front, IP20 rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eGeneral purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba648cf-p_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA648CF-P datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373833810265,"sku":"BA648CF-P","price":664.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba648cf_large_76e15f44-0edc-486b-97a1-3cdc8f09517b.png?v=1793874503"},{"product_id":"beka-ba688cf-p","title":"BEKA BA688CF-P – PROFIBUS PA Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA688CF-P\u003c\/strong\u003e is a PROFIBUS PA graphic display for panel mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS PA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eGraphic LCD, 120 × 64 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePanel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66 front, IP20 rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eGeneral purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba688cf-p_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA688CF-P datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373833843033,"sku":"BA688CF-P","price":1086.67,"currency_code":"GBP","in_stock":true},{"title":"With dual alarms","offer_id":60373833875801,"sku":"BA688CF-P-ALM","price":1345.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba688cf_large_ece2c434-8700-4c50-b27c-a017f0aa869a.png?v=1793874503"},{"product_id":"beka-ba444df-p","title":"BEKA BA444DF-P – PROFIBUS PA Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA444DF-P\u003c\/strong\u003e is an intrinsically safe PROFIBUS PA process indicator for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS PA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC subject to the applicable intrinsic safety limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5-digit LCD, 20 mm digits, 31-segment bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous-area protection\u003c\/th\u003e\n\u003ctd\u003eIntrinsically safe Ex ia. Refer to BEKA certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba444df-p_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA444DF-P datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373833908569,"sku":"BA444DF-P","price":798.67,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba444df_large_78add297-70b9-424d-a9bc-91463e1008f2.png?v=1793874502"},{"product_id":"beka-ba484df-p","title":"BEKA BA484DF-P – PROFIBUS PA Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA484DF-P\u003c\/strong\u003e is an intrinsically safe PROFIBUS PA graphic display for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS PA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC subject to the applicable intrinsic safety limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eGraphic LCD, 120 × 64 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous-area protection\u003c\/th\u003e\n\u003ctd\u003eIntrinsically safe Ex ia. Refer to BEKA certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba484df-p_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA484DF-P datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373833974105,"sku":"BA484DF-P","price":1276.0,"currency_code":"GBP","in_stock":true},{"title":"With dual alarms","offer_id":60373834006873,"sku":"BA484DF-P-ALM","price":1534.67,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba484df_large_3d9c1837-3c00-4242-a3ae-75b989210322.png?v=1793874502"},{"product_id":"beka-ba644df-p","title":"BEKA BA644DF-P – PROFIBUS PA Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA644DF-P\u003c\/strong\u003e is a PROFIBUS PA process indicator for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS PA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5-digit LCD, 20 mm digits, 31-segment bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eGeneral purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba644df-p_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA644DF-P datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373834039641,"sku":"BA644DF-P","price":761.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba644df_large_b4609991-7d68-498d-a7b9-fa73bc9f9d07.png?v=1793874502"},{"product_id":"beka-ba684df-p","title":"BEKA BA684DF-P – PROFIBUS PA Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA684DF-P\u003c\/strong\u003e is a PROFIBUS PA graphic display for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS PA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eGraphic LCD, 120 × 64 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eGeneral purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba684df-p_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA684DF-P datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373834072409,"sku":"BA684DF-P","price":1197.33,"currency_code":"GBP","in_stock":true},{"title":"With dual alarms","offer_id":60373834105177,"sku":"BA684DF-P-ALM","price":1456.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba684df_large_7b812c7b-97f6-4c55-b54e-8d2fe50fa2c0.png?v=1793874502"},{"product_id":"beka-ba418cf-f","title":"BEKA BA418CF-F – FOUNDATION Fieldbus Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA418CF-F\u003c\/strong\u003e is an intrinsically safe FOUNDATION Fieldbus process indicator for panel mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eFOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInteroperability\u003c\/th\u003e\n\u003ctd\u003eITK 6.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFunction block\u003c\/th\u003e\n\u003ctd\u003eOne Input Selector (IS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC subject to the applicable intrinsic safety limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5-digit LCD, 20 mm digits, 31-segment bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePanel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFront dimensions\u003c\/th\u003e\n\u003ctd\u003e144 × 72 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66 front, IP20 rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous-area protection\u003c\/th\u003e\n\u003ctd\u003eIntrinsically safe Ex ia. Refer to BEKA certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba418cf-f_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA418CF-F datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373834137945,"sku":"BA418CF-F","price":805.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba418cf_large_36dca3ba-388e-450f-b2e1-ce6cbeb11e28.png?v=1793874501"},{"product_id":"beka-ba448cf-f","title":"BEKA BA448CF-F – FOUNDATION Fieldbus Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA448CF-F\u003c\/strong\u003e is an intrinsically safe FOUNDATION Fieldbus process indicator for panel mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eFOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC subject to the applicable intrinsic safety limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5-digit LCD, 20 mm digits, 31-segment bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePanel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66 front, IP20 rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous-area protection\u003c\/th\u003e\n\u003ctd\u003eIntrinsically safe Ex ia. Refer to BEKA certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba448cf-f_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA448CF-F datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373834170713,"sku":"BA448CF-F","price":850.67,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba448cf_large_70dfba74-0441-46fa-ba87-76959053bfcc.png?v=1793874501"},{"product_id":"beka-ba488cf-f","title":"BEKA BA488CF-F – FOUNDATION Fieldbus Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA488CF-F\u003c\/strong\u003e is an intrinsically safe FOUNDATION Fieldbus graphic display for panel mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eFOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInteroperability\u003c\/th\u003e\n\u003ctd\u003eITK 6.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC subject to the applicable intrinsic safety limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eGraphic LCD, 120 × 64 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePanel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66 front, IP20 rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous-area protection\u003c\/th\u003e\n\u003ctd\u003eIntrinsically safe Ex ia. Refer to BEKA certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba488cf-f_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA488CF-F datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373834203481,"sku":"BA488CF-F","price":1426.67,"currency_code":"GBP","in_stock":true},{"title":"With dual alarms","offer_id":60373834236249,"sku":"BA488CF-F-ALM","price":1685.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba488cf_large_f4d00200-cd0a-49cf-a400-9a4eead97a48.png?v=1793874500"},{"product_id":"beka-ba618cf-f","title":"BEKA BA618CF-F – FOUNDATION Fieldbus Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA618CF-F\u003c\/strong\u003e is a FOUNDATION Fieldbus process indicator for panel mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eFOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInteroperability\u003c\/th\u003e\n\u003ctd\u003eITK 6.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFunction block\u003c\/th\u003e\n\u003ctd\u003eOne Input Selector (IS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5-digit LCD, 20 mm digits, 31-segment bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePanel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66 front, IP20 rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eGeneral purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba618cf-f_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA618CF-F datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373834269017,"sku":"BA618CF-F","price":776.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba618cf_large_ded6553f-a6c5-4551-ac5d-e6469e21baeb.png?v=1793874500"},{"product_id":"beka-ba648cf-f","title":"BEKA BA648CF-F – FOUNDATION Fieldbus Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA648CF-F\u003c\/strong\u003e is a FOUNDATION Fieldbus process indicator for panel mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eFOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5-digit LCD, 20 mm digits, 31-segment bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePanel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66 front, IP20 rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eGeneral purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba648cf-f_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA648CF-F datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373834301785,"sku":"BA648CF-F","price":822.67,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba648cf_large_e57bb93e-2420-4b9e-93f7-ea95ae0d4277.png?v=1793874500"},{"product_id":"beka-ba688cf-f","title":"BEKA BA688CF-F – FOUNDATION Fieldbus Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA688CF-F\u003c\/strong\u003e is a FOUNDATION Fieldbus graphic display for panel mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eFOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInteroperability\u003c\/th\u003e\n\u003ctd\u003eITK 6.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eGraphic LCD, 120 × 64 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePanel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66 front, IP20 rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eGeneral purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba688cf-f_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA688CF-F datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373834334553,"sku":"BA688CF-F","price":1356.0,"currency_code":"GBP","in_stock":true},{"title":"With dual alarms","offer_id":60373834367321,"sku":"BA688CF-F-ALM","price":1614.67,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba688cf_large_3f7cf6b0-d679-45a2-8152-14bac02f48ec.png?v=1793874500"},{"product_id":"beka-ba414df-f","title":"BEKA BA414DF-F – FOUNDATION Fieldbus Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA414DF-F\u003c\/strong\u003e is an intrinsically safe FOUNDATION Fieldbus process indicator for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eFOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInteroperability\u003c\/th\u003e\n\u003ctd\u003eITK 6.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFunction block\u003c\/th\u003e\n\u003ctd\u003eOne Input Selector (IS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC subject to the applicable intrinsic safety limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5-digit LCD, 20 mm digits, 31-segment bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous-area protection\u003c\/th\u003e\n\u003ctd\u003eIntrinsically safe Ex ia. Refer to BEKA certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba414df-f_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA414DF-F datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373834400089,"sku":"BA414DF-F","price":938.67,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba414df_large_05d63852-fe23-4036-adef-b44e527a7bd8.png?v=1793874500"},{"product_id":"beka-ba444df-f","title":"BEKA BA444DF-F – FOUNDATION Fieldbus Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA444DF-F\u003c\/strong\u003e is an intrinsically safe FOUNDATION Fieldbus process indicator for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eFOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC subject to the applicable intrinsic safety limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5-digit LCD, 20 mm digits, 31-segment bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous-area protection\u003c\/th\u003e\n\u003ctd\u003eIntrinsically safe Ex ia. Refer to BEKA certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba444df-f_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA444DF-F datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373834432857,"sku":"BA444DF-F","price":957.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba444df_large_2e6b09bd-2e44-4e62-b795-dc04d0b2374d.png?v=1793874499"},{"product_id":"beka-ba484df-f","title":"BEKA BA484DF-F – FOUNDATION Fieldbus Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA484DF-F\u003c\/strong\u003e is an intrinsically safe FOUNDATION Fieldbus graphic display for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eFOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInteroperability\u003c\/th\u003e\n\u003ctd\u003eITK 6.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC subject to the applicable intrinsic safety limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eGraphic LCD, 120 × 64 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazardous-area protection\u003c\/th\u003e\n\u003ctd\u003eIntrinsically safe Ex ia. Refer to BEKA certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba484df-f_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA484DF-F datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373834498393,"sku":"BA484DF-F","price":1502.67,"currency_code":"GBP","in_stock":true},{"title":"With dual alarms","offer_id":60373834531161,"sku":"BA484DF-F-ALM","price":1761.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba484df_large_8418efd5-b9b9-4e34-8ccb-2259b4921a45.png?v=1793874499"},{"product_id":"beka-ba614df-f","title":"BEKA BA614DF-F – FOUNDATION Fieldbus Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA614DF-F\u003c\/strong\u003e is a FOUNDATION Fieldbus process indicator for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eFOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInteroperability\u003c\/th\u003e\n\u003ctd\u003eITK 6.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFunction block\u003c\/th\u003e\n\u003ctd\u003eOne Input Selector (IS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5-digit LCD, 20 mm digits, 31-segment bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eGeneral purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba614df-f_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA614DF-F datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373834563929,"sku":"BA614DF-F","price":913.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba614df_large_681fbf15-677e-4191-873e-758307369a61.png?v=1793874499"},{"product_id":"beka-ba644df-f","title":"BEKA BA644DF-F – FOUNDATION Fieldbus Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA644DF-F\u003c\/strong\u003e is a FOUNDATION Fieldbus process indicator for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eFOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5-digit LCD, 20 mm digits, 31-segment bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eGeneral purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba644df-f_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA644DF-F datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373834596697,"sku":"BA644DF-F","price":930.67,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba644df_large_29a89c9e-c85d-454e-9527-050530b199f4.png?v=1793874499"},{"product_id":"beka-ba684df-f","title":"BEKA BA684DF-F – FOUNDATION Fieldbus Indicators \u0026 Display","description":"\u003cp\u003eThe \u003cstrong\u003eBEKA BA684DF-F\u003c\/strong\u003e is a FOUNDATION Fieldbus graphic display for field mounting.\u003c\/p\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eFOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003eFieldbus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInteroperability\u003c\/th\u003e\n\u003ctd\u003eITK 6.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess variables\u003c\/th\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus voltage\u003c\/th\u003e\n\u003ctd\u003e9–32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus current\u003c\/th\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eGraphic LCD, 120 × 64 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eField mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eGeneral purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eManufacturer documentation\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba684df-f_datasheet.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBEKA BA684DF-F datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"BEKA Associates","offers":[{"title":"Standard","offer_id":60373834727769,"sku":"BA684DF-F","price":1438.67,"currency_code":"GBP","in_stock":true},{"title":"With dual alarms","offer_id":60373834760537,"sku":"BA684DF-F-ALM","price":1697.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/1441\/4937\/files\/ba684df_large_e9c2cfb1-0ac4-43d0-8798-f435446637f2.png?v=1793874498"}],"url":"https:\/\/stockshedmetering.com\/collections\/fieldbus-displays.oembed","provider":"Stockshed Metering Limited","version":"1.0","type":"link"}